Dacor cooktops & rangetops repair

The RNTT365GB controls gas with electronics instead of knobs, and its manual has a full display code table: “b” for a burner locked after three failed tries, “F” for an abnormal flame, “H” for a hot surface, and clock codes Flt00 to Flt0A. The five-resets-in-15-minutes lockout (Flt06) is a safety feature, not a failure.

Most “b” and Flt0A calls come down to wet igniters, misplaced caps or a gas supply issue. When those are ruled out, the control and valves are tested.

Key Features

  • 36-inch drop-in touch-control gas cooktop
  • Electronic burner control with per-burner displays
  • Clock display with Flt error codes
  • LP variant RNTT365GBLP

Most Common Issues on This Model

01

“b” burner locked after three failed ignitions

02

Flt06 reset lockout

03

Flt0A all burners locked

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

Book Your Repair Today

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 875-1755 now

FAQ

Dacor RNTT365GB FAQ

Wait 15 minutes. It is a lockout after five resets.

It failed to light three times and was locked. Check the cap and igniter, then reset.